Development and perceived usability evaluation of an interactive smartphone application for the teaching of hemodynamics and evaluation of arterial pulse pressure variation

Abstract

Background

The use of fluids is the most frequently used therapy for circulatory shock. Its inadequate use has adverse effects, requiring hemodynamic goals, highlighting the use of pulse pressure variation due to its high accuracy. One of the problems related to this method is the difficulties in measuring the pulse pressure variation (PPV) in most monitors for clinical use. We assessed the qualitative aspects of perceived usability of a smartphone application (app), which, based on a photograph of the patient's arterial pulse wave, can help measure PPV and help in the diagnosis and management of shock cases.

Methods

To assess the software perceived usability, we used the System Usability Scale (SUS) applied to 30 physicians in 2 tertiary hospitals in Brazil. The software accuracy was measured using a sequence of 3 images with different values ​​of pulse pressure variation, comparing the obtained values ​​ with the gold standard. The educational interface of the app was evaluated qualitativelyfrom the spontaneous testimonies of the selected test participants.The project was approved by the Research Ethics Committee of Centro Universitário Christus.

Results

The analysis showed an average SUS of 86.3 points on a scale of 1–100 (above 80.3 is considered the best in terms of interface). The assessment of the application's accuracy when evaluating pulse pressure variation showed that the average variation of the measurements taken by the participants was small, with a good measure of repeatability and reproducibility. The app's educational interface was qualitatively evaluated, being praised by the users.

Conclusions

It can be concluded that the developed mobile application showed excellent qualitative aspects of perceived usability results. More studies with this app will be required to evaluate the potential to help professionals with hemodynamic evaluation in emergency and intensive care settings.

Peer Review reports

Background

Shock is a common condition in critical care, affecting approximately a third of the patients in the intensive care unit (ICU) [1]. Early and adequate hemodynamic support of patients in shock is crucial to prevent organ dysfunction deterioration and failure. Fluid therapy aiming to improve microvascular blood flow and increase cardiac output is an essential part of the treatment of any type of shock, but despite being the most widely used treatment in intensive care worldwide, fluid resuscitation is a frequent source of doubts, diagnostic and therapeutic errors and academic questions in the ICU [2,3,4].

Plasma expansion with intravenous fluids is the most frequently used treatment in most cases of shock; however, excess fluid leads to increased mortality in critically-ill patients, especially septic patients, due to increased mechanical ventilation time, acute kidney injury, respiratory distress syndrome and intra-abdominal hypertension. On the other hand, in cases of fluid responsiveness in hypotensive patients, its use improves cardiac output and systemic perfusion, with an impact on mortality [5,6,7].

Among the several hemodynamic parameters that have been described, pulse pressure variation (PPV), derived from the analysis of the arterial waveform and its contour, has shown to be the best predictor of fluid responsiveness when performed under ideal conditions (patients in sinus rhythm, intubated and mechanically ventilated, not making any spontaneous respiratory efforts, with at least 8 mL/kg of tidal volume, without changes in chest wall compliance) [8]. A recent meta-analysis that included 22 studies showed a sensitivity of 88% with a specificity of 89% [9]. The formula, initially described by Michard et al. is as follows:

$$\cdot \;{\text{PPV}} = {1}00 \times \left( {{\text{PPmax}}{-}{\text{Ppmin}}} \right)/{\text{PPmax}} + {\text{PPmin}}/{2}$$

where PPmax is the highest pulse pressure in the inspiratory period and PPmin is the lowest pulse pressure in the expiratory period.

PPV is a reflection of cardiopulmonary interactions. Cardiac output varies when a patient breathes both spontaneously and on mechanical ventilation. The more the cardiac output varies with breaths, the more likely the patient is to respond to fluids with an increase in stroke volume. Using this simple principle, clinicians can use the common arterial line tracing to assess the patient's responsiveness to volume [10]. Despite being technically easy to perform and cost-effective, PPV is underutilized in clinical practice due to the lack of knowledge of the variable by the physicians or, mainly, due to the difficulty in measuring it in conventional use clinical monitors. Some arterial catheters with specific transducers that analyze the pulse wave contour based on automated algorithms generate the stroke volume variation (SVV) continuously, but at a high cost, making its routine application difficult [11].

The cost associated with modern intensive care is extremely high and new modalities that assist monitoring and decision making at low cost are therefore essential, especially in low-income regions such as Brazil. With the expansion of mobile phone technology comes a new opportunity for potentially cost-effective monitoring systems for intensive care interventions. We assessed the qualitative aspects of perceived usability of an application for mobile devices aiming to assist in the optimization of fluid therapy in critically-ill patients, helping to measure the arterial pulse pressure variation, evaluating its usability and measurement accuracy.

Methods

The app for mobile devices was developed for Android and iOS, using the Java language, with the participation of a multidisciplinary team consisting of two professors from the medical course and one from Computer Sciences, a systems analyst, a computer programmer and a graphic designer. Software development kits (SDKs) were used for specific Android and Apple devices. For Android platforms, the Android Studio's IDE (Integrated Development Environment) tools, Google's Android with APIs (Application Programming Interface) and the OpenCV (Open-Source Computer Vision) library were used. For the development, a work team was assembled with the authors and the programming team. A flow of activities was established, which involved monthly meetings from the creation of the prototype version on. At each meeting, demands were identified and passed on to the software programmer and incorporated into the app. Improvement suggestions and qualitative feedback made by users in the testing phases were incorporated into the program after the final analysis.

Satisfaction with perceived usability was assessed based on the version of the System Usability Scale (SUS) translated into Brazilian Portuguese [12]. The SUS contains ten questions that aim to measure the usability of different products and services, being technologically versatile to evaluate various products and services [13], including websites, hardware, multimodal systems, voice command systems, mobile applications and clinical systems [14]. The original version of SUS was developed by John Brooke in 1986 as part of a usability engineering program to allow the user to evaluate the usability of a particular product or service quickly and easily. When SUS is used, participants are asked to score the following 10 items with one of five responses that range from Strongly Agree to Strongly disagree (see Table 2 for the 10 questions contained in the SUS survey). To estimate usability, the contributions of each scoring item were added together. For the positively worded questions [1, 3, 5, 7, 9], the score contribution is the answer value minus 1. For the negatively worded questions [2, 4, 6, 8, 10], the contribution is equal to 5 minus the answer value. Subsequently, the values of the contributions of the 10 questions are added and multiplied by 2.5 to obtain the value of the SUS score.

Regarding the classification obtained by the score

  •  < 20.5 (worst imaginable)

  • 21 to 38.5 (poor)

  • 39.5 to 52 (average)

  • 53 to 73.5 (good)

  • 74 to 85.5 (excellent)

  • Greater than 86 (best imaginable)

After the evaluation by the SUS scale, participants were directly interviewed to provide an evaluation of positive and negative aspects, as well as suggestions for improvements in the use of the app, and they could freely answer this question.

After presenting the app installed on a smartphone, we made a brief explanation to each participant about the aim the research and the pulse pressure variation. To assess usability, the researcher initially operated the app and used it to take a photo containing the measurement on a patient’s monitor with an arterial line; subsequently, the participant operated the app for a few minutes and performed a measurement with a photo obtained by themselves, answering the structured questionnaire afterwards.

To assess the accuracy of the app's measurement, we used 3 photographs and compared several consecutive measurements by expert judges, as shown in the example below in Fig. 1.

Fig. 1
figure 1

Example of tracing used to measure accuracy—patient with septic shock of pulmonary focus, with hypotension and anuria, receiving vasoactive drugs, with 13% of pulse pressure variation (PPV) measurement

For composing the gold standard, we evaluated the results of pulse pressure variation with a multiparametric monitor and expert PPV manual annotations. (Philips Medical Systems; DX 2020 monitor) in patients with an arterial line, using invasive mechanical ventilation, with 6 mL per kg of tidal volume, without cardiac arrhythmias. The professionals were approached at their respective workplaces (ICU or surgical center) during their daily shifts. The professionals who performed the accuracy assessment were chosen by convenience, while complying with the prerequisites of knowing the software, working in intensive care, and knowing how to assess pulse pressure variation. Eight physicians were selected for this stage of the study.

The categorical quantitative results were presented as percentages and counts and the numerical ones as measures of central tendency. Kolmogorov–Smirnov normality tests were performed for numerical variables. After the abovementioned calculation (in the SUS section) to obtain the final SUS score, the mean score for all participants was calculated. Also, we presented the absolute and relative frequencies of each category in each questionnaire item. The chi-square test was used to verify association for categorical variables. The analysis of variance (ANOVA) method for measuring repeatability and reproducibility was used, which is a measurement system analysis technique that uses a random effect model of ANOVA to evaluate a measurement system. The evaluation of a measuring system is not limited to rulers and scales, for instance, but to all types of measuring instruments, test methods and other measuring systems. The expanded ANOVA R&R measurement system measures the amount of variability induced in measurements by the measurement system itself and compares it with the total variability observed to determine the feasibility of the measurement system. Values ​​of p < 0.05 were considered significant. The data obtained in the collection were tabulated and analyzed using the software IBM SPSS Statistics for Windows, version 23.0, Armonk, NY: IBM Corp. IBM Corp, released in 2015.

All methods were carried out in accordance with relevant guidelines and regulations. All patients who agreed to participate in the study signed the Free and Informed Consent Form and were previously informed about the conditions and objectives of the study. All of them were free to withdraw from the study at any time, without entailing any kind of damage to their physical or emotional integrity. The National Research Ethics Commission of Brazil (CONEP), in accordance with the attributions defined in CNS Resolution number 466 of 2012 and CNS Operational Standard number 001 of 2013, approved the research project.

Results

The app, temporarily called ‘Hemodynamics’, contains two practical features, an interface to help measure the PPV, an educational support on the hemodynamic monitoring topic, as well as a tutorial explaining the use of the software. The illustration is shown below. By clicking on the item “patients and measurements”, the physician will be redirected to another screen containing the registered patients, where data on the patients and measurements will be stored, with the date and time of the measurement performance. Based on a photo selected from the smartphone library or the cell phone camera, two comparative rulers can be used to measure the PPV; the red colored one should select the pulse wave with the highest amplitude (usually during inspiration) and the blue colored one, the wave with the lowest amplitude (Fig. 2).

Fig. 2
figure 2

Application home screen and measurement example using the app tool. The red lines should overlap the higher systolic and the higher diastolic pressure (PPMAX) and the blue lines should overlap the lower systolic and the lower diastolic pressure (PPMIN)

By clicking on educational support, the app directs the physician to a screen with several examples of hemodynamic monitoring in intensive care for educational purposes and to a session of clinical cases with several emergency and ICU scenarios. The available text is in accordance with the updated guidelines of medical literature, containing information on the topics: Pulse contour assessment (LiDCO®, Vigileo®/FLotrac®, PICCO®), pulmonary artery catheter—with description of the catheter and normal and altered variables, with the differential diagnosis of different types of shock, ultrasonography, central venous pressure and a text on the use of the arterial line and pulse pressure variation (Fig. 3).

Fig. 3
figure 3

Example of the application educational tool. In the image on the left, list of tool options for hemodynamic monitoring: Pulse contour analysis, pulmonary artery catheter, echocardiography, arterial line, central venous pressure, pulse pressure variation. At the Center, example of the pulse contour evaluation interface. Right image, example of the text and figures from ultrasound use

The third item directs the physician to two tutorial videos, one on pulse pressure variation and the other on the app utilization. Both videos are available on the internet and can be freely accessed.

We evaluated the developed app regarding its usability according to the SUS in 30 physicians from different specialties, 15 working in Internal Medicine, 4 in General Surgery, 2 in Anesthesiology, 6 in Intensive Care, 2 in Neurology and 1 in Emergency Care. The mean age was 34.6 years (ranging from 25 to 49), with 21 men and 9 women. The mean time since graduation was 8.9 ± 6.7 years, with an average time of experience in the ICU of 5.66 ± 6.58 years, and 29 (96.7%) already routinely use educational apps on cell phones, as shown in Table 1.

Table 1 Sample description

The final SUS score was 86.5, ranging from 60 to 100, with 90 for male and 82.5 for female users, being considered an A+ or better imaginable grade in terms of perceived usability (Table 2).

Table 2 Usability assessment according to the SUS scale

In the analysis of reproducibility and repeatability, most of the variation found by the measurement device is due to the adequate variation of the measured objects, with approximately 30% of the variation due to repeatability and reproducibility, with a p-value < 0.001 as shown in Fig. 4a. The graph showing the measurements taken by each participant shows that the average variation of the several measurements taken by the participants was small (Fig. 4b). The sample amplitude graph by participant shows that the mean amplitude, 3.37, was low in relation to the averages of the obtained measurements (Fig. 4c).

Fig. 4
figure 4

a Reproducibility and repeatability analysis. There was roughly 30% variation, due mainly to part-to-part variations. b Graph of measurements taken by each participant, showing low variability among examiners. c Amplitude graph. Note the random pattern evidencing the absence of biased sampling. UCL Upper Control Limit, LCL Lower Control Limit, R Average Range

When evaluating the free answers of the participants about suggestions and positive and negative aspechts of the app, we observed that the most praised aspects were the practicality of the app, its ease of use, and the quick calculation of the PPV. As criticism and suggestion for improvement, one user commented: “I suggest, when you take a picture of the monitor, a tool that allows you to easily rotate and align the horizontal axis". There was also criticism of the sensitivity of the cell phone touch, which according to some users made it difficult to use the app. No other remarks were mentioned.

Discussion

In this study, we present the assessment of the qualitative aspects of perceived usability of a mobile app that allows the measurement of pulse pressure variation that had a usability result perceived by the participants of 86%, considered excellent, as well as a good good measure of repeatability and reproducibility.

Despite being a hemodynamic variable with low cost of use and high accuracy in some subgroups of patients, it was found that both in the literature and in practice, PPV is underused. One can infer some reasons for this fact. There is a relative technical difficulty in obtaining data on conventional monitors, despite a minority of modern monitors. In the United States of America, only 15.2% of anesthesiologists use PPV as a volume guide in the operating room, although the same study showed that in 95.4% of high-risk surgeries, the patient has an invasive arterial line. In contrast, 72% routinely use the CVP [15], a static parameter known to be less accurate for fluid evaluation. In this same study, in an intensive care setting, to assess responsiveness, North-American anesthesiologists more frequently use blood pressure, urinary output, clinical experience and CVP, rather than PPV.

The cost associated with modern intensive care is high, comprising up to 30% of total hospital costs and 1% of the gross domestic product in the United States. In Australia, the average cost of a critical patient per day is on average US$4,375.00, approximately R$25,000.00 reais at the current exchange rate [16]. The pulmonary artery catheter adds US$14,400 on average to the cost of a patient's hospital stay [17]. The use of minimally-invasive technology with the FloTrac® system has a cost per patient of around R$1,500.00 reais. With the expansion of mobile telephone technology, a new opportunity for the monitoring of potentially cost-effective intensive care interventions can be evaluated in future economic evaluations.

The first automatic calculation algorithms for PPV were part of commercial monitoring systems such as the PICCO system. In 2004, a new algorithm was described, aiming to estimate the PPV index in arterial pressure [18]. The method uses automatic detection algorithms, data smoothing, and rank order filters to continuously estimate PPV. For this new PPV estimation, the algorithm was described in detail to ensure reproducibility, aiming to allow researchers to implement it in their own software packages and to be able to automatically determine PPV from digitally stored ABP (This new algorithm facilitated the dissemination of the method since, considering its open access feature, the companies that manufacture medical equipment are also free to implement it as part of their monitoring systems. Given the recent developments in this area, several medical device-manufacturing companies have continued to develop monitoring systems that include proprietary algorithms to automatically monitor dynamic fluid responsiveness indicators [19].

The Capstesia® program (Galenic App, Vitoria-Gasteiz, Spain), which can be installed on smartphones or tablets, is a mobile application for pulse wave analysis with cardiac output estimation, using a digital extraction technology [20], with a good estimate of stroke volume variation when compared to the traditional SVV measurement methods [21], showing substantial agreement between cardiac output values ​​produced by the Vigileo® monitor and the app in patients undergoing cardiac surgery [22]. We still do not have an impact analysis on mortality, cost and hospital length of stay with this new monitoring app. This app, however, is not available in Brazil and requires a monthly subscription payment, making it difficult to use it in our country.

Our study evaluated the usability perceived by the participants, being one of the first in the world to present results in this sense. The usability perceived by the participants was 86%, which is considered excellent. Other studies have also evaluated the reproducibility of other applications for measuring PPV, reaching results of 9%, close to those found in this study [20].

The calculation of pulse pressure variation in our app does not use automated algorithms, but a manual measurement. This potentially decreases the sensitivity of the method through the potentiation of errors made by the user, being an important disadvantage of the method. On the other hand, it makes the app lighter and more flexible, not requiring a continuous internet connection, allowing its use in more remote areas.

Considering the social changes regarding the use of smart devices, mobile devices will increasingly become a key component of medical students’ learning and the use of a mobile device as an educational tool has shown to have a positive effect on the acquisition of knowledge and skills among medical students and residents [23].

The lack of apps of similar function does not allow a direct comparison in terms of usability with other articles. Other apps used in smartphones for various functions (cardiac arrest assistance, diabetes management, major burns, among others) use the SUS scale in a similar way for their evaluation [24].

Our study has several limitations. Firstly, the population was studied in two intensive care centers from tertiary hospitals, making a broader generalization of results difficult. Secondly, our evaluation focused mainly on qualitative aspects of perceived usability, and the assessment of the effectiveness of the interventions based on the data provided by the app should be the subject of future investigations. Finally, showing the participants how to use the application immediately prior to the testing session may have introduced bias on the generality of the results. However, the app has a self-instructing session that may fill this gap.

Conclusions

Our software showed acceptable qualitative aspects of perceived usabilityusability, good repeatability and reproducibilityand potential benefit in teaching and in medical care for critically-ill patients. Comparative studies to analyze its effectiveness in actual clinical practice scenarios are necessary for its wider use.

Availability of data and materials

The datasets generated and/or analysed during the current study are not publicly available due to Brazilian ethical laws but are available from the corresponding author on reasonable request.

References

  1. Vincent J-L, De Backer D. Circulatory shock. N Engl J Med. 2013;369(18):1726–34.

    Article  CAS  PubMed  Google Scholar 

  2. Berg DD, Bohula EA, van Diepen S, Katz JN, Alviar CL, Baird-Zars VM, et al. Epidemiology of shock in contemporary cardiac intensive care units. Circ Cardiovasc Qual Outcomes. 2019;12(3):e005618.

    Article  PubMed  Google Scholar 

  3. Douglas IS, Alapat PM, Corl KA, Exline MC, Forni LG, Holder AL, et al. Fluid response evaluation in sepsis hypotension and shock: a randomized clinical trial. Chest. 2020;158(4):1431–45.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Vandervelden S, Malbrain ML. Initial resuscitation from severe sepsis: one size does not fit all. Anaesthesiol Intensive Ther. 2015;47:s44-55.

    Article  PubMed  Google Scholar 

  5. Alvarado Sanchez JI, Amaya Zuniga WF, Monge Garcia MI. Predictors to intravenous fluid responsiveness. J Intensive Care Med. 2018;33(4):227–40.

    Article  PubMed  Google Scholar 

  6. Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Curr Opin Crit Care. 2015;21(5):388–94.

    Article  PubMed  Google Scholar 

  7. Chaves RCF, Correa TD, Neto AS, Bravim BA, Cordioli RL, Moreira FT, et al. Assessment of fluid responsiveness in spontaneously breathing patients: a systematic review of literature. Ann Intensive Care. 2018;8(1):21.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642–7.

    Article  PubMed  Google Scholar 

  9. Yang X, Du B. Does pulse pressure variation predict fluid responsiveness in critically ill patients? A systematic review and meta-analysis. Crit Care. 2014;18(6):650.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Roberson RS. Respiratory variation and cardiopulmonary interactions. Best Pract Res Clin Anaesthesiol. 2014;28(4):407–18.

    Article  PubMed  Google Scholar 

  11. Chen Y, Fu Q, Mi WD. Effects of stroke volume variation, pulse pressure variation, and pleth variability index in predicting fluid responsiveness during different positive end expiratory pressure in prone position. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2015;37(2):179–84.

    PubMed  Google Scholar 

  12. Tenório JM, Cohrs FM, Sdepanian VL, Pisa IT, Marin HdF. Desenvolvimento e Avaliação de um Protocolo Eletrônico para Atendimento e Monitoramento do Paciente com Doença Celíaca. Revista de Informática Teórica e Aplicada. 2010;17(2):2011.

    Google Scholar 

  13. Brooke J. SUS: a quick and dirty usability scale. Usability Eval Ind. 1995;189.

  14. Grier RA, Bangor A, Kortum P, Peres SC. The system usability scale: beyond standard usability testing. In: Proceedings of the human factors and ergonomics society annual meeting. 2013;57(1):187–91.

  15. Cannesson M, Pestel G, Ricks C, Hoeft A, Perel A. Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists. Crit Care. 2011;15(4):R197.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Hicks P, Huckson S, Fenney E, Leggett I, Pilcher D, Litton E. The financial cost of intensive care in Australia: a multicentre registry study. Med J Aust. 2019;211(7):324–5.

    Article  PubMed  Google Scholar 

  17. Clermont G, Kong L, Weissfeld LA, Lave JR, Rubenfeld GD, Roberts MS, et al. The effect of pulmonary artery catheter use on costs and long-term outcomes of acute lung injury. PLoS ONE. 2011;6(7): e22512.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Aboy M, McNames J, Thong T, Phillips CR, Ellenby MS, Goldstein B. A novel algorithm to estimate the pulse pressure variation index deltaPP. IEEE Trans Biomed Eng. 2004;51(12):2198–203.

    Article  PubMed  Google Scholar 

  19. Cannesson M, Aboy M, Hofer CK, Rehman M. Pulse pressure variation: where are we today? J Clin Monit Comput. 2011;25(1):45–56.

    Article  PubMed  Google Scholar 

  20. Desebbe O, Joosten A, Suehiro K, Lahham S, Essiet M, Rinehart J, et al. A novel mobile phone application for pulse pressure variation monitoring based on feature extraction technology: a method comparison study in a simulated environment. Anesth Analg. 2016;123(1):105–13.

    Article  PubMed  Google Scholar 

  21. Joosten A, Jacobs A, Desebbe O, Vincent JL, Sarah S, Rinehart J, et al. Monitoring of pulse pressure variation using a new smartphone application (Capstesia) versus stroke volume variation using an uncalibrated pulse wave analysis monitor: a clinical decision making study during major abdominal surgery. J Clin Monit Comput. 2019;33(5):787–93.

    Article  PubMed  Google Scholar 

  22. Santiago-López J, León-Ramírez V, Hernández-Ramírez S, Vásquez-Márquez PI, Castellanos-Olivares A. Concordance in the measurement of cardiac output. Vigileo vs. Capstesia. Rev Med Inst Mex Seguro Soc. 2018;56(2):136–42.

    PubMed  Google Scholar 

  23. Chase TJG, Julius A, Chandan JS, Powell E, Hall CS, Phillips BL, et al. Mobile learning in medicine: an evaluation of attitudes and behaviours of medical students. BMC Med Educ. 2018;18(1):152.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Borycki EM, Monkman H, Griffith J, Kushniruk AW. Mobile usability testing in healthcare: methodological approaches. Stud Health Technol Inform. 2015;216:338–44.

    PubMed  Google Scholar 

Download references

Acknowledgements

To all participants of the study.

Funding

None to report.

Author information

Authors and Affiliations

Authors

Contributions

Author’s contributions were as follows: OAB, EMBF, DABSA, LSM, HALR, have made substantial contributions to conception and design and on revising the manuscript critically for relevant intellectual content. All authors approved the final manuscript as submitted and agree to be accountable for all aspects of the work.

Corresponding author

Correspondence to Hermano Alexandre Lima Rocha.

Ethics declarations

Ethics approval and consent to participate

All patients who agreed to participate in the study signed the Free and Informed Consent Form and were previously informed about the conditions and objectives of the study. All of them were free to withdraw from the study at any time, without entailing any kind of damage to their physical or emotional integrity. The National Research Ethics Commission of Brazil (CONEP), in accordance with the attributions defined in CNS Resolution number 466 of 2012 and CNS Operational Standard number 001 of 2013, approved the research project.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Barbosa, O.A., Marçal, E., Araújo, D.A.B.S. et al. Development and perceived usability evaluation of an interactive smartphone application for the teaching of hemodynamics and evaluation of arterial pulse pressure variation. BMC Med Inform Decis Mak 23, 31 (2023). https://doi.org/10.1186/s12911-023-02131-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12911-023-02131-5

Keywords