Skip to main content

Table 5 Sensitivity of identifying the abnormal cells

From: Artificial intelligence of digital morphology analyzers improves the efficiency of manual leukocyte differentiation of peripheral blood

Professional title

Blasts

Promyelocytes

Myelocytes

Metamyelocytes

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

Junior

64.55

79.83

43.43

66.86

27.45

70.66

34.65

74.79

Intermediate

78.06

87.3

42.86

77.71

29.06

78.4

22.39

71.55

Professional title

Reactive lymphocytes

Nucleated RBCs

Plasma cells

Abnormal lymphocytes

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

Junior

48.44

78.67

78.67

98.41

36.3

43.48

42.36

46.91

Intermediate

48.74

85.48

83.98

99.03

44.13

44.35

38.55

55.27