Skip to main content

Table 3 Accuracy of identifying the abnormal cells1

From: Artificial intelligence of digital morphology analyzers improves the efficiency of manual leukocyte differentiation of peripheral blood

Professional title

Blasts

Promyelocytes

Myelocytes

Metamyelocytes

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

Junior

91.38

98.94

10.86

23.08

55.32

84.25

38.99

70.42

Intermediate

91.97

98.15

23.66

80

68.14

95.96

40.66

83.28

Professional title

Reactive lymphocytes

Nucleated RBCs

Plasma cells

Abnormal lymphocytes

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

No AI (%)

With AI (%)

Junior

16.46%

33.21%

97.48%

99.55%

97.66%

98.52%

47.65%

46.49%

Intermediate

30.38%

56.18%

97.53%

97.99%

100.00%

99.03%

37.46%

71.53%