Table 2 The results of R-wave extracted by making adaptive discrete wavelet transform

From: A particle swarm optimization improved BP neural network intelligent model for electrocardiogram classification

Types

ID

TP

FP

FN

Sensitive (Se)

Precision (P)

Vpb

15

15

0

0

1

1

Rbbb

15

15

0

0

1

1

Nb

15

15

0

0

1

1

Apb

15

14

1

1

0.9333

0.9333

Lbbb

15

14

1

1

0.9333

0.9333

  1. ID represents the number of heartbeats marked in the data