Table 2 Multi-level early alarm effect result of 200 clinical patients

From: A multi-level hypoglycemia early alarm system based on sequence pattern mining

Alarm level Actual hypoglycemia Early alarm False alarm Average early alarm time Sensitivity (%) False-positive (%) Missing alarm rate (%)
I 78 67 21 20.61 85.90 23.86 14.10
II 219 176 37 27.66 80.37 17.37 19.63
III 342 267 42 33.80 78.07 13.59 21.93
\