Table 6 Classifier performance on the training and test sets at the closest threshold to a recall of 0.55 on the training set for each topic

From: Studying the potential impact of automated document classification on scheduling a systematic review update

  

TRAINING SET CROSS-VALIDATION

TOPIC

THRESHOLD

TP

TN

FP

FN

Precision

Recall

F1

ADHD

−0.2466

155

2423

119

130

0.566

0.544

0.555

AEDs

−0.3302

57

1361

75

39

0.432

0.594

0.500

Antiemetics

−0.3550

70

2196

168

63

0.294

0.526

0.377

AtypicalAntipsychotics

−0.1696

375

3544

285

284

0.568

0.569

0.569

MSDrugs

−0.2390

77

1699

75

61

0.507

0.558

0.531

NasalCorticosteroids

−0.3943

8

61

21

5

0.276

0.615

0.381

OveractiveBladder

−0.3461

57

695

128

46

0.308

0.553

0.396

ProtonPumpInhibitors

−0.2532

117

2235

98

87

0.544

0.574

0.558

Sedatives

−0.2617

79

1583

74

66

0.516

0.545

0.530

  1. True positives (TP), true negatives (TN), false positives (FP), false negatives (FN), F1 measure (F1, the harmonic mean of precision and recall).