Skip to main content

Table 8 Cross-database test results for PTB-XL conversion from lead II

From: Electrocardiogram lead conversion from single-lead blindly-segmented signals

Lead

Shared encoder

Individual encoders

r (avg.)

r (med.)

RMSE

SSIM

r (avg.)

r (med.)

RMSE

SSIM

I

0.74

0.80

0.25

0.31

0.72

0.79

0.26

0.29

III

0.44

0.50

0.32

0.50

0.45

0.52

0.32

0.50

aVR

−0.38

−0.53

0.72

0.09

−0.39

−0.55

0.72

0.09

aVL

−0.33

−0.44

0.64

0.23

−0.33

−0.45

0.67

0.17

aVF

0.83

0.90

0.19

0.61

0.84

0.92

0.19

0.62

V1

0.79

0.87

0.17

0.91

0.81

0.89

0.16

0.91

V2

0.71

0.79

0.22

0.84

0.72

0.82

0.21

0.85

V3

0.61

0.68

0.30

0.66

0.62

0.70

0.30

0.66

V4

0.64

0.71

0.31

0.31

0.66

0.74

0.32

0.32

V5

0.79

0.86

0.22

0.37

0.80

0.87

0.23

0.39

V6

0.85

0.91

0.18

0.58

0.85

0.91

0.18

0.58