Skip to main content

Table 5 Test results of the U-Net used for multi-lead conversion from lead I, with shared or individual encoders

From: Electrocardiogram lead conversion from single-lead blindly-segmented signals

Lead

Shared encoder

Individual encoders

r (avg.)

r (med.)

RMSE

SSIM

r (avg.)

r (med.)

RMSE

SSIM

II

0.49

0.54

0.37

0.17

0.50

0.55

0.36

0.19

III

0.44

0.49

0.35

0.53

0.46

0.52

0.35

0.55

aVR

0.89

0.92

0.14

0.92

0.90

0.93

0.13

0.93

aVL

0.76

0.84

0.25

0.45

0.77

0.85

0.26

0.46

aVF

0.26

0.29

0.43

0.28

0.28

0.32

0.42

0.27

V1

0.81

0.88

0.18

0.88

0.79

0.88

0.19

0.88

V2

0.73

0.80

0.23

0.81

0.70

0.77

0.25

0.80

V3

0.67

0.73

0.28

0.70

0.67

0.74

0.29

0.68

V4

0.59

0.65

0.33

0.48

0.62

0.71

0.32

0.48

V5

0.62

0.73

0.30

0.31

0.64

0.73

0.30

0.28

V6

0.66

0.75

0.26

0.39

0.67

0.77

0.26

0.39