Skip to main content

Table 5 Performance characteristics of the three-hourly data experiment

From: Applying artificial neural network for early detection of sepsis with intentionally preserved highly missing real-world data for simulating clinical situation

Hours prior to onset

AUC (95% CI)

Accuracy

Sensitivity

Specificity

1–3

0.792 (0.780–0.805)

0.730

0.796

0.665

4–6

0.784 (0.773–0.794)

0.721

0.777

0.665

7–9

0.767 (0.749–0.784)

0.703

0.754

0.654

10–12

0.769 (0.759–0.779)

0.711

0.762

0.660

13–15

0.771 (0.755–0.787)

0.716

0.775

0.642