From: Automated detection of activity onset after postictal generalized EEG suppression
2-Channel comb. | AUC | 3-Channel comb. | AUC |
---|---|---|---|
FP2, Fz | 0.80 | F7, FP2, Fz | 0.83 |
T7, Cz | 0.79 | T7, FP2, Cz | 0.83 |
T7, FP2 | 0.79 | T7, FP2, Fz | 0.83 |
Fz, Cz | 0.78 | F7, T7, Cz | 0.82 |
T8, Cz | 0.78 | F7, Fz, Cz | 0.81 |
P7, P8 | 0.67 | P7, P8, T8 | 0.69 |