Table 3 Stepwise linear regression results for the outcomes satisfaction and intention to usea

From: Nurses’ perceptions, acceptance, and use of a novel in-room pediatric ICU technology: testing an expanded technology acceptance model

  Satisfaction Intention
Estimate (SE) t-value, p-value Estimate (SE) t-value, p-value
Intercept −0.79 (0.41) t = −1.90, p = 0.061 0.77 (0.22) t = 3.54, p < 0.001
Perceived ease of use, expanded 0.31 (0.10) t = 3.20, p = 0.002 b
Perceived usefulness for patient/family involvement 0.31 (0.10) t = 2.93, p = 0.004 b
Perceived usefulness for care delivery 0.45 (0.10) t = 4.41, p < 0.001 0.66 (0.07) t = 9.13, p < 0.001
Social influence: Patients/Family b 0.13 (0.06) t = 2.02, p = 0.046
  Adjusted R2 = 0.70 Adjusted R2 = 0.65
  1. aPerceived usefulness, traditional; social influence, institutional; and perceived training on system were not significant in either model, and are not included in this table
  2. bNot a statistically significant model covariate