Clinical data needs in the neonatal intensive care unit electronic medical record

Abstract

Background

The amount of clinical information that providers encounter daily creates an environment for information overload and medical error. To create a more efficient EMR human-computer interface, we aimed to understand clinical information needs among NICU providers.

Methods

A web-based survey to evaluate 98 data items was created and distributed to NICU providers. Participants were asked to rate the importance of each data item in helping them make routine clinical decisions in the NICU.

Results

There were 23 responses (92% – response rate) with participants distributed among four clinical roles. The top 5 items with the highest mean score were daily weight, pH, pCO2, FiO2, and blood culture results. When compared by clinical role groupings, supervisory physicians gave individual data item ratings at the extremes of the scale when compared to providers more responsible for the daily clinical care of NICU patients.

Conclusion

NICU providers demonstrate a need for large amounts of EMR data to help guide clinical decision making with differences found when comparing by clinical role. When creating an EMR interface in the NICU there may be a need to offer options for varying degrees of viewable data densities depending on clinical role.

Peer Review reports

Background

The combination of continuous monitoring and the ability of the electronic medical record (EMR) to store large amounts of data creates a potential for information overload in the intensive care (ICU) setting [1]. The potential dangers underlying this information overload relate to the inability of practitioners to discern pertinent from irrelevant information [2] and the accumulation of errors of cognition and performance associated with data corruption [3, 4].

A possible way to combat the risks of information overload may center on the development and implementation of advanced health information technologies (HITs). The Institute of Medicine and the United States Department of Health and Human Services have both advocated for the enhanced creation and use of efficient EMRs [5]. Recently, the HIT for Economic and Clinical Health (HITECH) Act was enacted which has allocated federal funds to aid in this endeavor [6].

Previous EMR implementation experiences in academic institutions have been met with conflicting outcomes. Although most institutions have demonstrated improved outcomes, increased productivity, and fewer errors [3, 710] associated with EMR use, there is still guarded optimism on how best to design and integrate EMRs into clinical practice [11].

The development of a novel EMR human-computer interface, Ambient Warning and Response Evaluation (AWARE), at our institution resulted in improved performance and decreased errors of cognition in the adult ICU setting when compared to the standard EMR system [3]. The creation of this specific interface was based on expert panel input and data utilization models designed to assess the specific information needs of the unit [12, 13]. This design methodology is in contrast to the vendor-generated platforms most commonly used in hospital EMRs [14].

The critically ill pediatric population is a unique group with specific medical information needs [15, 16]. Additionally, there are special considerations that need to be taken into account when creating EMR interfaces for use specifically in the neonatal intensive care unit (NICU) [17]. As a result there have been standards suggested to help guide the creation of pediatric and neonatal specific EMRs [18, 19]. The creation of these guidelines underscore the importance of creating efficient EMR human-computer interfaces, such as AWARE, to help decrease medical errors and improve clinical care.

In order to create an end-user designed patient-centered EMR interface we endeavored to better understand the exact clinical information needs of NICU practitioners. In the present study we address this gap in knowledge by a survey to determine what data NICU providers find useful in clinical decision making for inclusion into future EMR human-computer interfaces.

Methods

Study design

A web-based survey was conducted at Mayo Clinic, Rochester, MN, an academic tertiary health care center, equipped with a comprehensive EMR. The Mayo Clinic NICU has 26 level III beds and admits approximately 350 infants per year. The survey was conducted among NICU providers of varying clinical roles. The study was approved by the Institutional Review Board (IRB) at Mayo Clinic. The study was deemed exempt from consent requirements by the IRB (13–003930).

Study subjects

Twenty-five subjects for the survey were selected from 4 clinical role designations; attending physicians (AP), neonatal fellows (NF), neonatal nurse practitioners (NP), and pediatric residents (PR). The AP group consisted of staff neonatologists and 1 neonatal hospitalist. NPs with significant clinical duty commitments (>50% of shifts occurring in the level III setting) were invited to participate. The PR group consisted of senior pediatric residents with NICU experience within the last year.

Data collection

Instruments

An expert panel, consisting of 2 APs and 1 NF, reviewed our current EMR and identified 98 unique data items that are available to clinical users. Using a 7-point Likert scale [ranging from not needed (0) to absolutely necessary (6)] subjects were asked to rate each of the 98 data items according to their opinion as to its importance in helping make routine clinical decisions in the NICU. Of note, only a 0 (not needed) or 6 (absolutely necessary) score was given a categorical description. Scores between these extremes (1–5) were exclusively numerical in nature.

Procedures

The survey utilized the Research Electronic Data Capture (REDCap) web-based application [20] and was distributed to the study participants via an embedded e-mail link to the survey. Two e-mail reminders were generated to enhance survey participation. The identity of participants and survey results were kept confidential from all subjects and investigators.

Data analysis

Survey responses were collected and tabulated by the REDCap tool. The mean score (MS) was calculated for each data item with items then ranked in descending order of MS for generation of the median value and interquartile ranges. The percentage of participants ranking each individual data item as not needed or absolutely necessary was also determined. The MS for each data item was also stratified according to the respondent’s clinical role. For these analyses APs and NFs were grouped together (AP/NF) as they mainly perform supervisory roles, with NPs and PRs being grouped (NP/PR) as they often are charged with carrying out most pre-rounding, rounding, and post-rounding duties.

Statistics

All descriptive statistics and comparison of means (Wilcoxon’s rank sum test) were performed in JMP (v 9.0.1, SAS Institute, Cary, NC); p < .05 was considered statistically significant. TABLEAU® software (Seattle, WA) was used for data visualization. Study format, design, and statistical analyses were done in accordance with similar published studies performed at our institution and under the guidance of statistical support [12, 21].

Results

Twenty-five survey requests were distributed with 23 responses obtained, giving a response rate of 92%. All 8 APs and 2 NFs completed the survey with 4 NPs and 9 PRs participating in the study.

Figure 1 shows each of the 98 data items listed by descending MS. The top 5 data items with the highest MS were daily weight, pH, pCO2, FiO2, and blood culture results. The median MS was 4.5 (maximum 6) with 71% of the data items falling within the top 2 quartiles when distributed by proportional quarters. The lowest 5 rated data items were RBC distribution width (RDW), QTc value, mean corpuscular volume (MCV), total number of transfusions, and hematocrit.

Figure 1
figure 1

Data item ratings. Data items in descending order of the mean score (average) as rated by NICU providers to the perceived importance in guiding clinical care. Proportional quartiles are demonstrated by shading of the graph bars. Also shown are the percentages of respondents that rated each data item as absolutely necessary and not needed.

Also displayed in Figure 1 is the percentage of respondents that rated each item as absolutely necessary or not needed. Daily weight received the highest percentage of responders (73%) rating it as an absolutely necessary data item. Sixteen of the 98 items (16%) received an absolutely necessary rating by more than 50% of respondents. The 3 items with the lowest MS also received the highest percentage of respondents rating each data item as not needed. Only 1 item (QTc value) was rated by more than 20% of respondents as not needed.

Stratifying individual data item MSs by clinical role groupings (AP/NF versus NP/PR) resulted in an alteration of the order of highest ranking data items (Table 1). Seven data items (daily weight, pH, pCO2, FiO2, blood culture results, ventilator mode, and chest X-ray) were among the top 10 rated items in both groupings. Similarly, 6 data items (total urine output, hematocrit, blood type, MCV, RDW, and QTc value) were among the 10 lowest rated items in both groups.

Table 1 Top ten data items by clinical role

Figure 2 shows the results of the distribution of MSs for every data item stratified by clinical role groupings. The AP/NF group rated data items significantly higher than the NP/PR group with the overall means of all data item MSs being 4.5 and 4.3 respectively (p = 0.01). Figure 2 also illustrates the same data analyses displayed in a proportion of densities chart (no statistical analyses performed). This chart demonstrates that the AP/NF group generated more data item MSs at the extremes of the scale with a larger proportion of both higher and lower rated data items compared to NP/PRs, who produced a larger proportion of moderately rated data items.

Figure 2
figure 2

Variance by clinical role. (A) Variance in the individual data item mean scores stratified by clinical role (AP – attending physician; NF – neonatal fellow; NP – nurse practitioner; PR – pediatric resident). Data are displayed in box-whisker graphs (median, interquartile range, total range) with the lighter horizontal line showing the grand mean. (B) Proportion of density chart illustrating the distribution of data item mean scores by clinical role (no statistical analyses performed).

Discussion

We conducted a survey among NICU providers to assess the clinical information needs in an effort to create a more effective EMR human-computer interface. To our knowledge this is the first study attempting to assess these specific needs in a systematic way. Our survey had a high response rate with participants distributed among 4 distinct clinical role designations. The data demonstrates that when making clinical decisions NICU providers rely on a significant proportion of the large amounts of objective data provided to them by the EMR. This is evidenced by the fact that nearly three-fourths of the data items were ranked within the top 2 proportional quartiles with only 3 items contained in the bottom quartile. In addition, there was a large difference at the extremes of the rankings with many more respondents ranking items as absolutely necessary as compared to not needed. This finding of high EMR-derived data needs is consistent with the finding that NICU providers prefer objective data compared to verbal communication or clinical notes as their primary clinical information source [22].

The distribution of scores aligns with what one would expect clinically. Of the 10 highest rated data items, 7 were related to a respiratory parameter, one often associated with ventilatory management. It is well known that a significant number of major morbidities among NICU patients are respiratory in nature with a significant amount of daily management related to this system [23, 24]. As well, the highest rated item, daily weight, is vital for daily medication and fluid calculations and is marked as one the most fundamental data items required in the development of pediatric HITs [18, 19].

In addition to our findings when respondents were grouped as a whole, there were important findings when data item ratings were stratified by clinical role. By grouping in this manner (AP/NF and NP/PR) we attempted to better understand the clinical information needs of users with similar clinical responsibilities. The results of these comparisons have clinical practicality and can offer insights into the appropriate development of HITs best suited to address differing clinical needs. NP/PRs are often responsible for most pre-rounding and rounding duties and are the primary care provider of NICU patients throughout a day [2527]. As a result, providers in this role have a need for access to large amounts of data items, without much discrimination of importance, in order to collect all the necessary information for dissemination in multidisciplinary patient rounds and in the clinical note. In contrast, supervisory physicians (AP/NFs) often give a disproportionate significance to a smaller set of data items that aid them in making the most critical decisions and care plans with certain data items being lightly regarded or even ignored.

These descriptions of differing roles are supported by our study as AP/NF data item ratings generated bimodal peaks at the extremes of the scale with a more consistent and evenly distributed rating pattern produced by NP/PRs. These findings may suggest that appropriate EMR interfaces for the NICU setting should include different viewing options that are catered to the primary clinical role of the user. Interfaces for supervisory physicians may include less data items that highlight selected, critically relevant data while those for NPs and PRs may be similar to current EMR interfaces with most patient data items readily available and viewable. Further studies are needed to verify these findings and better elucidate what specific data items should be included in a proposed limited data option that can be utilized by supervisory physicians and others (i.e. consulting services), where large amounts of data can be safely omitted without patient care compromise.

Our study has some limitations which include the relatively small number of participants and a single institution survey. Our survey included 23 participants mainly due to the relatively low volume and staffing needs of our NICU. However, we were able to include every AP and NF with a large proportion of NP and PR participation. Despite the low absolute numbers, we feel these survey results accurately reflect the opinions of the care providers and can be used to help guide interface development. In addition, it is important to recognize that these results may reflect a local practice and should be generalized to other settings with these limitations in mind. Regardless, in the development of patient-centered clinical tools, the clinician’s perspective from a single hospital play a more important role than population based observations.

Another limitation of this study involves asking respondents to rate the importance of data items in helping make “routine clinical decision”. We are aware that there are often times when clinical needs reach beyond the scope of what would be considered “routine” and require a different data requirement. It would be difficult to speculate the change in ratings, if any, if the word “routine” were removed from the survey. Regardless, we wanted the results of the survey to portray the ideas of providers in the most common and frequent clinical scenarios and designed the survey as such. We feel that options for viewing different levels of data density, as discussed earlier, would be a way to overcome this obstacle and provide adequate levels of data catered to each clinical situation.

This is the first step in a process of creating and adapting an EMR human-computer interface that involves a design allowing for end-users to influence its final product. A methodical process such as this is important in creating an environment where the implementation of new technology is well accepted and tailored to the needs of the users [28]. In addition, the design of our study creates an opportunity for replication in other centers in an effort to compare and contrast the information needs among providers in various NICU settings.

Conclusion

Our study illustrates the myriad of data items available to NICU caregivers for use in clinical decision making and demonstrates that providers at our institution feel that a majority of those data items are important with significant differences found when comparing by clinical role. This creates the need to develop patient-centered EMR human-computer interfaces and other HITs that present vast amounts of data [1] in a way that is easily synthesized [17] and offers options for varying degrees of viewable data densities depending on clinical role. In this way one can better create EMR interfaces that are relevant to the clinical expectations of providers while at the same time achieve a goal of reducing information overload and lowering the risk for medical errors [3, 13].

Abbreviations

AP:

Attending physician

AWARE:

Ambient warning and response evaluation

EMR:

Electronic medical record

HIT:

Health information technology

MS:

Mean score

NICU:

Neonatal intensive care unit

NF:

Neonatal fellow

NP:

Neonatal nurse practitioner

PR:

Pediatric resident.

References

  1. Manor-Shulman O, Beyene J, Frndova H, Parshuram CS: Quantifying the volume of documented clinical information in critical illness. J Crit Care. 2008, 23 (2): 245-250. 10.1016/j.jcrc.2007.06.003.

    Article  PubMed  Google Scholar 

  2. Potter AK, Johnson DP: Extracting the pertinent from the irrelevant. Minn Med. 1994, 77 (4): 58-

    CAS  PubMed  Google Scholar 

  3. Ahmed A, Chandra S, Herasevich V, Gajic O, Pickering BW: The effect of two different electronic health record user interfaces on intensive care provider task load, errors of cognition, and performance. Crit Care Med. 2011, 39 (7): 1626-1634. 10.1097/CCM.0b013e31821858a0.

    Article  PubMed  Google Scholar 

  4. Pickering BW, Hurley K, Marsh B: Identification of patient information corruption in the intensive care unit: using a scoring tool to direct quality improvements in handover. Crit Care Med. 2009, 37 (11): 2905-2912. 10.1097/CCM.0b013e3181a96267.

    Article  PubMed  Google Scholar 

  5. Institute of Medicine CoQoHCiA: To Err Is Human: Building a Safer Health System. 1999, Washington, DC: National Academy Press

    Google Scholar 

  6. HITECH Programs & Advisory Committees. [http://www.healthit.gov/policy-researchers-implementers/hitech-programs-advisory-committees]

  7. Bates DW: Using information technology to reduce rates of medication errors in hospitals. BMJ. 2000, 320 (7237): 788-791. 10.1136/bmj.320.7237.788.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Bates DW, Leape LL, Cullen DJ, Laird N, Petersen LA, Teich JM, Burdick E, Hickey M, Kleefield S, Shea B, Vander Vliet M, Seger DL: Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA. 1998, 280 (15): 1311-1316. 10.1001/jama.280.15.1311.

    Article  CAS  PubMed  Google Scholar 

  9. Longhurst CA, Parast L, Sandborg CI, Widen E, Sullivan J, Hahn JS, Dawes CG, Sharek PJ: Decrease in hospital-wide mortality rate after implementation of a commercially sold computerized physician order entry system. Pediatrics. 2010, 126 (1): 14-21. 10.1542/peds.2009-3271.

    Article  PubMed  Google Scholar 

  10. Palma JP, Sharek PJ, Longhurst CA: Impact of electronic medical record integration of a handoff tool on sign-out in a newborn intensive care unit. J Perinatol. 2011, 31 (5): 311-317. 10.1038/jp.2010.202.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Sittig DF, Ash JS, Zhang J, Osheroff JA, Shabot MM: Lessons from “Unexpected increased mortality after implementation of a commercially sold computerized physician order entry system”. Pediatrics. 2006, 118 (2): 797-801. 10.1542/peds.2005-3132.

    Article  PubMed  Google Scholar 

  12. Pickering BW, Gajic O, Ahmed A, Herasevich V, Keegan MT: Data utilization for medical decision making at the time of patient admission to ICU. Crit Care Med. 2013, 41 (6): 1502-1510. 10.1097/CCM.0b013e318287f0c0.

    Article  PubMed  Google Scholar 

  13. Pickering BW, Herasevich V, Ahmed A, Gajic O: Novel representation of clinical information in the ICU: developing user interfaces which reduce information overload. Appl Clin Inform. 2010, 1 (2): 116-131. 10.4338/ACI-2009-12-CR-0027.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  14. Frassica JJ: CIS: where are we going and what should we demand from industry?. J Crit Care. 2004, 19 (4): 226-233. 10.1016/j.jcrc.2004.10.001.

    Article  PubMed  Google Scholar 

  15. Kaushal R, Bates DW, Landrigan C, McKenna KJ, Clapp MD, Federico F, Goldmann DA: Medication errors and adverse drug events in pediatric inpatients. JAMA. 2001, 285 (16): 2114-2120. 10.1001/jama.285.16.2114.

    Article  CAS  PubMed  Google Scholar 

  16. Brannon TS: Ad hoc versus standardized admixtures for continuous infusion drugs in neonatal intensive care: cognitive task analysis of safety at the bedside. AMIA Annu Symp Proc. 2006, 862-

    Google Scholar 

  17. Palma JP, Brown PJ, Lehmann CU, Longhurst CA: Neonatal informatics: optimizing clinical data entry and display. Neoreviews. 2012, 13 (2): 81-85. 10.1542/neo.13-2-e81.

    Article  PubMed  PubMed Central  Google Scholar 

  18. Spooner SA: Special requirements of electronic health record systems in pediatrics. Pediatrics. 2007, 119 (3): 631-637. 10.1542/peds.2006-3527.

    Article  PubMed  Google Scholar 

  19. Kim GR, Lehmann CU: Pediatric aspects of inpatient health information technology systems. Pediatrics. 2008, 122 (6): e1287-e1296. 10.1542/peds.2008-2963.

    Article  PubMed  Google Scholar 

  20. Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG: Research electronic data capture (REDCap)–a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009, 42 (2): 377-381. 10.1016/j.jbi.2008.08.010.

    Article  PubMed  Google Scholar 

  21. Herasevich V, Ellsworth MA, Hebl JR, Brown MJ, Pickering BW: Information needs for the OR and PACU electronic medical record. Appl Clin Inform. 2014, 5 (3): 630-641. 10.4338/ACI-2014-02-RA-0015.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  22. Brown PJ, Borowitz SM, Novicoff W: Information exchange in the NICU: what sources of patient data do physicians prefer to use?. Int J Med Inform. 2004, 73 (4): 349-355. 10.1016/j.ijmedinf.2004.03.001.

    Article  PubMed  Google Scholar 

  23. Lemons JA, Bauer CR, Oh W, Korones SB, Papile LA, Stoll BJ, Verter J, Temprosa M, Wright LL, Ehrenkranz RA, Fanaroff AA, Stark A, Carlo W, Tyson JE, Donovan EF, Shankaran S, Stevenson DK: Very low birth weight outcomes of the National Institute of Child health and human development neonatal research network, January 1995 through December 1996. NICHD Neonatal Research Network. Pediatrics. 2001, 107 (1): E1-10.1542/peds.107.1.e1.

    Article  CAS  PubMed  Google Scholar 

  24. Kusuda S, Fujimura M, Sakuma I, Aotani H, Kabe K, Itani Y, Ichiba H, Matsunami K, Nishida H: Morbidity and mortality of infants with very low birth weight in Japan: center variation. Pediatrics. 2006, 118 (4): e1130-e1138. 10.1542/peds.2005-2724.

    Article  PubMed  Google Scholar 

  25. Karlowicz MG, McMurray JL: Comparison of neonatal nurse practitioners’ and pediatric residents’ care of extremely low-birth-weight infants. Arch Pediatr Adolesc Med. 2000, 154 (11): 1123-1126. 10.1001/archpedi.154.11.1123.

    Article  CAS  PubMed  Google Scholar 

  26. Mitchell-DiCenso A, Guyatt G, Marrin M, Goeree R, Willan A, Southwell D, Hewson S, Paes B, Rosenbaum P, Hunsberger M, Baumann A: A controlled trial of nurse practitioners in neonatal intensive care. Pediatrics. 1996, 98 (6 Pt 1): 1143-1148.

    CAS  PubMed  Google Scholar 

  27. Wallman C: Advanced practice in neonatal nursing. Pediatrics. 2009, 123 (6): 1606-1607.

    Article  PubMed  Google Scholar 

  28. Rikli J, Huizinga B, Schafer D, Atwater A, Coker K, Sikora C: Implementation of an electronic documentation system using microsystem and quality improvement concepts. Adv Neonatal Care. 2009, 9 (2): 53-60. 10.1097/ANC.0b013e31819d4df4.

    Article  PubMed  Google Scholar 

Pre-publication history

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marc A Ellsworth.

Additional information

Competing interests

Mayo Clinic and authors (BP, VH) hold the patent on AWARE technology referenced in this paper. None of the authors have financial competing interests to disclose as no funding was acquired for this study.

Authors’ contributions

ME designed and distributed the survey, performed data analyses and drafted the manuscript. TL was part of the expert panel who developed the survey. BP participated in study design. VH participated in study design, was part of expert panel, performed data analyses and helped to draft the manuscript. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.

Authors’ original file for figure 1

Authors’ original file for figure 2

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ellsworth, M.A., Lang, T.R., Pickering, B.W. et al. Clinical data needs in the neonatal intensive care unit electronic medical record. BMC Med Inform Decis Mak 14, 92 (2014). https://doi.org/10.1186/1472-6947-14-92

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/1472-6947-14-92

Keywords