Skip to main content

Table 3 Summary diagnostic accuracy derived from random-effects models

From: A systematic review of the diagnostic accuracy of physical examination for the detection of cirrhosis

FINDING

STUDIES

SENSITIVITY

95%Cl

SPECIFICITY

95% Cl

Ascites

7

0.34

0.22–0.49.

0.95

0.89–0.98

Collateral circulation

3

0.42

0.26–0.61

0.94

0.71–0.99

Encephalopathy

3

0.15

0.06–0.33

0.98

0.97–0.99

Firm liver

3

0.68

0.55–0.79

0.75

0.62–0.85

Jaundice

3

0.36

0.25–0.48

0.85

0.80–0.89

Spider angiomata

8

0.50

0.39–0.61

0.88

0.75–0.95